What is the maximum distance between pillars?
The maximum span between columns for normal structures is 7.5 m and minimum spacing is 2.5 m. How does the increase in the distance between columns affect the cost of the structure? Increasing the span between reinforced concrete columns increase the cost of the structure.
How do I select a column size for a building?
Column size depends on various factors like number of floors, span between two column, is it short or slender, For 5m span 1 storey/single floor/ground floor/G+0 residential building, it could be 230×230, for G+1 it could be 230x 300mm, for G+2 it could be 300x 300mm,for G+3 it could be 300x 380mm and for G+4 it could …
What is the maximum height of column?
The maximum height of a column is 24 m. Columns height from 20 m to 24 m can be manufactured as one piece (uncut), and composite. Fire resistance of precast concrete columns – R150 (according to the DBN V.
What is the size of column for G 2 storey house?
Column size for 2 storey (G+1) building:- For this general thumb rule, we will assume a structure of G+1 (2 storey) residential building, using standard 5″ walls, size of an RCC column should be 9”x 12” (230mm x 300mm) with 6 bars of 12mm Fe500 Steel with m20 grade of concrete and stirrups of T8@6″C/C.
Are 9 x 12 RCC columns safe for g+1 floors?
This setup of 9″ x 12″ RCC columns is safe for G+1 Floors. There are a lot of other considerations, but this is just a thumb rule. For the above column setup, a span of up to 5 meters is quite safe. One can use beams of size 9″ X 12″ (225 MM x 300MM) with a slab thickness of 5″ (125 MM) cast in M20 concrete for spans up to 5m.
What is the minimum diameter of a 9×9 steel column?
The minimum steel in a 9″ x 9″ column is 4 bars of 12 MM with stirrups of 8 MM steel rings at a distance of 150 MM centre to centre. In a 9″ x 12″ column, I add two more bars, to take the total to 6 bars of 12 MM diameter.
What is the minimum size of an RCC column?
Minimum size of an RCC column should not be less than 9” x 12” (225mm x 300mm) with 4 bars of 12 MM Fe415 Steel. These days the minimum I use in my projects is 9″ x 12″ (225 mm x 300mm) with 6 bars of 12 MM Fe500 steel. You can never go wrong with strong columns.
How does the size of the columns depend on the beam?
Contact me. The size of the columns depends on the total load on the columns. There are axial loads and lateral loads. Large beam spans induce bending moment not only in the beams, but also in columns which are pulled by the stresses in the beams.